... set forth in Table 5 - B . Such occupancies shall not exceed , in area or height , the limits specified in Sections 504 , 505 and 506 and shall comply with the provisions of this section . 304.2.2 Special provisions . 304.2.2.1 ...
... set forth in Table 5 - B . Such occupancies shall not exceed , in area or height , the limits specified in Sections 504 , 505 and 506 and shall comply with the provisions of this section . 304.2.2 Special provisions . 304.2.2.1 ...
Page 1-257
... specified in Section 2406 and hinged shower doors in all occupancies as specified in Section 2407 . 3. Interior glass and glazing shall comply with Section 2404.1 . EXCEPTION : Groups R and U Occupancies . 4. Skylights and sloped ...
... specified in Section 2406 and hinged shower doors in all occupancies as specified in Section 2407 . 3. Interior glass and glazing shall comply with Section 2404.1 . EXCEPTION : Groups R and U Occupancies . 4. Skylights and sloped ...
Page 1-283
... set forth in Section 2902. Fixtures located within unisex toilet and bathing rooms shall be included in determining the number of fixtures provided in an occupancy . 2902.2 Group A Occupancies . In Group A Occupancies , at least one ...
... set forth in Section 2902. Fixtures located within unisex toilet and bathing rooms shall be included in determining the number of fixtures provided in an occupancy . 2902.2 Group A Occupancies . In Group A Occupancies , at least one ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood