... square feet ( 4645 m2 ) shall be provided with standby pow- er systems that are capable of operating the public ... square feet ( 13 935 m2 ) of gross leasable area , by 40 for covered mall buildings containing between 150,001 and ...
... square feet ( 4645 m2 ) shall be provided with standby pow- er systems that are capable of operating the public ... square feet ( 13 935 m2 ) of gross leasable area , by 40 for covered mall buildings containing between 150,001 and ...
Page 1-95
... square feet ( 92.9 m2 ) or less in area and 50 feet ( 15 240 mm ) or less in height where curtains , scenery or other combustible hangings are not retractable vertically . Combustible hangings shall be limited to a single main curtain ...
... square feet ( 92.9 m2 ) or less in area and 50 feet ( 15 240 mm ) or less in height where curtains , scenery or other combustible hangings are not retractable vertically . Combustible hangings shall be limited to a single main curtain ...
Page 1-397
... square feet ( 2.78 m2 ) per occupant for the minimum number of plumbing fixtures . 1 : 1-25 2 : 26-75 3 : 76-125 4 : 126-200 5 : 201-300 6 : 301-400 Over 400 , add one fixture for each additional 200 males or 150 females . For the ...
... square feet ( 2.78 m2 ) per occupant for the minimum number of plumbing fixtures . 1 : 1-25 2 : 26-75 3 : 76-125 4 : 126-200 5 : 201-300 6 : 301-400 Over 400 , add one fixture for each additional 200 males or 150 females . For the ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood