... Stairways . 1003.3.3.1 General . Every stairway having two or more risers serving any building or portion thereof shall comply with the requirements of Section 1003.3.3 . For the purposes of Section 1003.3.3 , the term " stairway ...
... Stairways . 1003.3.3.1 General . Every stairway having two or more risers serving any building or portion thereof shall comply with the requirements of Section 1003.3.3 . For the purposes of Section 1003.3.3 , the term " stairway ...
Page 1-110
... Stairways open on one or both sides shall have guardrails as required by Section 509 . 1003.3.3.8 Alternative stairways . 1003.3.3.8.1 Circular stairways . Circular stairways conform- ing to the requirements of this section may be used ...
... Stairways open on one or both sides shall have guardrails as required by Section 509 . 1003.3.3.8 Alternative stairways . 1003.3.3.8.1 Circular stairways . Circular stairways conform- ing to the requirements of this section may be used ...
Page 1-119
... stairway not meeting the definition of an exterior stairway shall comply with the requirements for inte- rior stairways . 1006.3.3.2 Construction . Exterior exit stairways shall be constructed based on type of construction requirements ...
... stairway not meeting the definition of an exterior stairway shall comply with the requirements for inte- rior stairways . 1006.3.3.2 Construction . Exterior exit stairways shall be constructed based on type of construction requirements ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood