Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 87
Page 1-79
... THICKNESS FACE - TO - FACE2 ( inches ) x 25.4 for mm MATERIAL ITEM NUMBER CONSTRUCTION 4 Hr . 3 Hr . 2 Hr . 1 Hr . 1 ... thickness , units at least 40 percent solid . Two cells in wall thickness , units at least 43 percent solid . Two ...
... THICKNESS FACE - TO - FACE2 ( inches ) x 25.4 for mm MATERIAL ITEM NUMBER CONSTRUCTION 4 Hr . 3 Hr . 2 Hr . 1 Hr . 1 ... thickness , units at least 40 percent solid . Two cells in wall thickness , units at least 43 percent solid . Two ...
Page 1-199
... thickness shall be the sums of the nominal thickness of the inner and outer wythes of the masonry . In walls composed of different classes of units and mortars , the ratio of height or length to thickness shall not exceed that allowed ...
... thickness shall be the sums of the nominal thickness of the inner and outer wythes of the masonry . In walls composed of different classes of units and mortars , the ratio of height or length to thickness shall not exceed that allowed ...
Page 1-424
... Thickness Equivalent Recommended Minimum Thickness Equivalent1 GALVANIZED SHEET Decimal and Nominal Thickness Equivalent Recommended Minimum Thickness Equivalent1 Manufacturer's Standard Galvanized Sheet Gage No. ( inch ) ( mm ) 2 ...
... Thickness Equivalent Recommended Minimum Thickness Equivalent1 GALVANIZED SHEET Decimal and Nominal Thickness Equivalent Recommended Minimum Thickness Equivalent1 Manufacturer's Standard Galvanized Sheet Gage No. ( inch ) ( mm ) 2 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood