Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 20
Page 1-132
... water closet , provided that the room does not con- tain the only lavatory or water closet on the accessible level of the dwelling unit . 1106.6.4 Toilet and bathing fixtures . Toilet and bathing fix- tures shall comply with either ...
... water closet , provided that the room does not con- tain the only lavatory or water closet on the accessible level of the dwelling unit . 1106.6.4 Toilet and bathing fixtures . Toilet and bathing fix- tures shall comply with either ...
Page 1-133
... water closet are permitted to overlap the clear floor space . 2. Forward approach . 2.1 Sixty - six inches ( 1676 mm ) minimum , measured from the wall behind the water closet . 2.2 Forty - eight inches ( 1219 mm ) minimum , measured ...
... water closet are permitted to overlap the clear floor space . 2. Forward approach . 2.1 Sixty - six inches ( 1676 mm ) minimum , measured from the wall behind the water closet . 2.2 Forty - eight inches ( 1219 mm ) minimum , measured ...
Page 1-283
... water closets for each sex shall be provided at an approved location . At ... closet . Separate facilities shall be provided for each sex when the number ... water closet rooms in connection with food establish- ments where food is ...
... water closets for each sex shall be provided at an approved location . At ... closet . Separate facilities shall be provided for each sex when the number ... water closet rooms in connection with food establish- ments where food is ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood