Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 39
Page 1-165
... welding . 5.1 General . During the welding of any member or connec- tion that is designed to resist loads and forces required by this code . EXCEPTIONS : 1. Welding done in an approved fabricator's shop in accordance with Section 1701.7 ...
... welding . 5.1 General . During the welding of any member or connec- tion that is designed to resist loads and forces required by this code . EXCEPTIONS : 1. Welding done in an approved fabricator's shop in accordance with Section 1701.7 ...
Page 1-167
... welds over 3 feet ( 914 mm ) in length where the effective throat thickness is greater than 1 inch ( 25 mm ) , each 6 inches ( 152 mm ) of length or frac- tion thereof shall be considered one weld . 2. For complete penetration groove welds ...
... welds over 3 feet ( 914 mm ) in length where the effective throat thickness is greater than 1 inch ( 25 mm ) , each 6 inches ( 152 mm ) of length or frac- tion thereof shall be considered one weld . 2. For complete penetration groove welds ...
Page 1-180
... welded splices and other required welding of reinforcing bars shall be in- dicated on the design drawings or in the project specifications . ASTM reinforcing bar specifications , except for A 706 , shall be supplemented to require a ...
... welded splices and other required welding of reinforcing bars shall be in- dicated on the design drawings or in the project specifications . ASTM reinforcing bar specifications , except for A 706 , shall be supplemented to require a ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood