Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 56
Page 1-76
... wire ties [ 0.08 ′′ ( 2 mm ) diameter ] at each course of tile or 3/8 ′′ ( 9.5 mm ) metal mesh [ 0.046 " ( 1.2 mm ) diameter wire ] in horizontal joints ; limestone or trap - rock concrete fill1 extending 1 " ( 25 mm ) outside column on ...
... wire ties [ 0.08 ′′ ( 2 mm ) diameter ] at each course of tile or 3/8 ′′ ( 9.5 mm ) metal mesh [ 0.046 " ( 1.2 mm ) diameter wire ] in horizontal joints ; limestone or trap - rock concrete fill1 extending 1 " ( 25 mm ) outside column on ...
Page 1-143
... wire mesh shall be anchored to wood studs by galvanized steel wire furring nails at 4 inches ( 102 mm ) on center or by barbed galvanized nails at 6 inches ( 152 mm ) on center with a 11 / 8 - inch - minimum ( 29 mm ) penetration . The ...
... wire mesh shall be anchored to wood studs by galvanized steel wire furring nails at 4 inches ( 102 mm ) on center or by barbed galvanized nails at 6 inches ( 152 mm ) on center with a 11 / 8 - inch - minimum ( 29 mm ) penetration . The ...
Page 1-266
... wire 0.145 - inch ( 4.19 mm ) ( No. 8 B.W. gage ) wire 3/16 " diameter , mild steel rod2 Hangers for suspended ceilings 20 7/32 " diameter , mild steel rod2 22.5 22.0 Single hangers between beams4 8 12 16 1/4 " diameter , mild steel ...
... wire 0.145 - inch ( 4.19 mm ) ( No. 8 B.W. gage ) wire 3/16 " diameter , mild steel rod2 Hangers for suspended ceilings 20 7/32 " diameter , mild steel rod2 22.5 22.0 Single hangers between beams4 8 12 16 1/4 " diameter , mild steel ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood