Uniform Building Code, Volume 1International Conference of Building Officials, 1961 - Building laws |
From inside the book
Results 1-3 of 61
Page 185
... Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling 12 23-0 33-6 21-6 33-0 20-6 28-0 18-6 21-6 16 21-0 29-0 19-6 28-6 18-6 24-0 16-0 18-6 2 x 12 24 18-6 23-6 17-0 23-0 16-0 19-6 13-0 32 20-6 20-0 17-0 15-0 13-0 DESIGN ...
... Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling 12 23-0 33-6 21-6 33-0 20-6 28-0 18-6 21-6 16 21-0 29-0 19-6 28-6 18-6 24-0 16-0 18-6 2 x 12 24 18-6 23-6 17-0 23-0 16-0 19-6 13-0 32 20-6 20-0 17-0 15-0 13-0 DESIGN ...
Page 332
... ceiling required ) 62 52 42 32 Slab or arch ( no ceiling required ) 4 3 212 22 Hollow masonry Slab or arch 41 321 31 3 Slab with suspended ceiling on metal or wire lath , gypsum or portland cement plaster2 212 2 34 3/4 Reinforced ...
... ceiling required ) 62 52 42 32 Slab or arch ( no ceiling required ) 4 3 212 22 Hollow masonry Slab or arch 41 321 31 3 Slab with suspended ceiling on metal or wire lath , gypsum or portland cement plaster2 212 2 34 3/4 Reinforced ...
Page 334
... ceiling of metal or wire Fiberboard insulation or wood fiber and cement binder on top of deck , with ceiling , gypsum plaster sanded 1 : 2 12 1 8 3/4 A lath Steel or precast concrete joists with attached or sus- pended ceiling of metal ...
... ceiling of metal or wire Fiberboard insulation or wood fiber and cement binder on top of deck , with ceiling , gypsum plaster sanded 1 : 2 12 1 8 3/4 A lath Steel or precast concrete joists with attached or sus- pended ceiling of metal ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 19 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
89 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliance approved asbestos bars beams bolts Building Official building or structure ceiling cent chimneys clearance Code column combustible compression compression members compressive strength Continued designed diameter Douglas Fir dry standpipes eighteen inches 18 enclosure exceed exit exterior walls fire assembly Fire Zone fire-resistive rating firestopped floor flue or vent foot four inches frame furnaces gauge girders grade Group gypsum heaters height horizontal incombustible materials installed interior joints joists Laminations least live load located lumber masonry maximum metal mortar nails occupant load openings partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resist rivets roof shear sheathing six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch stairway standpipes steel studs Table tests tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard Ventilation vermiculite vertical width wood