... equal to the total dead load plus 25 per cent of the floor live load in storage and ware- house occupancies . WD We ... equal to one- fourth . For locations in Zone No. 2 “ Z ” shall be equal to one - half . For locations in Zone No. 3 ...
... equal to the total dead load plus 25 per cent of the floor live load in storage and ware- house occupancies . WD We ... equal to one- fourth . For locations in Zone No. 2 “ Z ” shall be equal to one - half . For locations in Zone No. 3 ...
Page 113
... equal to the re- quirements set forth in U.B.C. Standard No. 24-1-61 . When in contact with the ground , brick shall be of at least Grade MW . Where severe frost action occurs in the presence of moisture , brick shall be at least Grade ...
... equal to the re- quirements set forth in U.B.C. Standard No. 24-1-61 . When in contact with the ground , brick shall be of at least Grade MW . Where severe frost action occurs in the presence of moisture , brick shall be at least Grade ...
Page 146
... equal to the width of piece . H = 65 when length of split is approximately equal to one and one - half times width of piece . " For three - inch ( 3 " ) thick pieces of Select Structural , Construction and Standard Grades used as joists ...
... equal to the width of piece . H = 65 when length of split is approximately equal to one and one - half times width of piece . " For three - inch ( 3 " ) thick pieces of Select Structural , Construction and Standard Grades used as joists ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 19 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
89 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliance approved asbestos bars beams bolts Building Official building or structure ceiling cent chimneys clearance Code column combustible compression compression members compressive strength Continued designed diameter Douglas Fir dry standpipes eighteen inches 18 enclosure exceed exit exterior walls fire assembly Fire Zone fire-resistive rating firestopped floor flue or vent foot four inches frame furnaces gauge girders grade Group gypsum heaters height horizontal incombustible materials installed interior joints joists Laminations least live load located lumber masonry maximum metal mortar nails occupant load openings partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resist rivets roof shear sheathing six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch stairway standpipes steel studs Table tests tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard Ventilation vermiculite vertical width wood