... grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story . " ) BAY WINDOW is a rectangular , curved , or polygonal window , supported on a foundation extending beyond the main wall of the ...
... grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story . " ) BAY WINDOW is a rectangular , curved , or polygonal window , supported on a foundation extending beyond the main wall of the ...
Page 119
... Grade MW . Where severe frost action occurs in the presence of moisture , brick shall be at least Grade SW . ( c ) Brick Made from Sand - Lime . Building brick made from sand - lime shall be of a quality at least equal to the ...
... Grade MW . Where severe frost action occurs in the presence of moisture , brick shall be at least Grade SW . ( c ) Brick Made from Sand - Lime . Building brick made from sand - lime shall be of a quality at least equal to the ...
Page 147
... grades and grade combinations as set forth in Table No. 25 - A for solid sawn stress - grade lumber ; Tables No. 25 - B and No. 25 - C for Douglas fir plywood ; and Tables No. 25 - D , No. 25 - E and No. 25 - F for structural glued ...
... grades and grade combinations as set forth in Table No. 25 - A for solid sawn stress - grade lumber ; Tables No. 25 - B and No. 25 - C for Douglas fir plywood ; and Tables No. 25 - D , No. 25 - E and No. 25 - F for structural glued ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles