Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 20
Page 168
... WIDTH OF Module Grain Slope LAMINATION4 Scarf Slope Module Grain Slope Scarf Slope Module Grain Slope 0.1 4 to 14 ... NOMINAL WIDTH OF PLYWOOD SIZE SPECIES1 MEMBERS ( In Inches 168 TABLE NO . 25 - F ( Continued ) UNIFORM BUILDING CODE.
... WIDTH OF Module Grain Slope LAMINATION4 Scarf Slope Module Grain Slope Scarf Slope Module Grain Slope 0.1 4 to 14 ... NOMINAL WIDTH OF PLYWOOD SIZE SPECIES1 MEMBERS ( In Inches 168 TABLE NO . 25 - F ( Continued ) UNIFORM BUILDING CODE.
Page 191
... nominal in width and not less than ten inches ( 10 ′′ ) nominal in depth . Framed or glued - laminated arches which spring from the floor line and support floor loads shall be not less than eight inches ( 8 ′′ ) nominal in any dimension ...
... nominal in width and not less than ten inches ( 10 ′′ ) nominal in depth . Framed or glued - laminated arches which spring from the floor line and support floor loads shall be not less than eight inches ( 8 ′′ ) nominal in any dimension ...
Page 193
... nominal width and be proportional for other plank widths . Nail length shall be not less than two and one - half times the net thickness of each lamination . A single span deck shall have all laminations full length . A continuous deck ...
... nominal width and be proportional for other plank widths . Nail length shall be not less than two and one - half times the net thickness of each lamination . A single span deck shall have all laminations full length . A continuous deck ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles