... Ceiling Ceiling Ceiling Ceiling Ceiling Not Supporting Ceiling Not Supporting Supporting Ceiling Ceiling 16 7-0 8-0 6-0 7-0 5-0 5-6 3-0 3-6 2 x 4 24 32 12 16 2 x 6 24 32 LE DE 5-6 6-6 5-0 6-0 4-0 4-6 2-6 3-0 5-0 6-0 4-6 5-0 3-6 4-0 2-0 2-6 ...
... Ceiling Ceiling Ceiling Ceiling Ceiling Not Supporting Ceiling Not Supporting Supporting Ceiling Ceiling 16 7-0 8-0 6-0 7-0 5-0 5-6 3-0 3-6 2 x 4 24 32 12 16 2 x 6 24 32 LE DE 5-6 6-6 5-0 6-0 4-0 4-6 2-6 3-0 5-0 6-0 4-6 5-0 3-6 4-0 2-0 2-6 ...
Page 198
... Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling 12 25-6 32-0 24-0 31-0 22-6 26-6 17-6 20-6 16 23-6 28-0 22-0 27-6 22-0 23-6 15-6 18-0 2 x 12 24 20-0 23-6 19-6 23-0 16-6 19-6 13-0 15-0 32 17-6 20-6 17-0 20-0 14 ...
... Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling Ceiling 12 25-6 32-0 24-0 31-0 22-6 26-6 17-6 20-6 16 23-6 28-0 22-0 27-6 22-0 23-6 15-6 18-0 2 x 12 24 20-0 23-6 19-6 23-0 16-6 19-6 13-0 15-0 32 17-6 20-6 17-0 20-0 14 ...
Page 380
... ceiling required ) 62 52 42 32 Slab or arch ( no ceiling required ) 4 3 22 212 Hollow masonry Slab or arch 41 321 31 3 Slab with suspended ceiling on metal or wire lath , gypsum or portland cement plaster 22 2 3/4 3/4 Reinforced ...
... ceiling required ) 62 52 42 32 Slab or arch ( no ceiling required ) 4 3 22 212 Hollow masonry Slab or arch 41 321 31 3 Slab with suspended ceiling on metal or wire lath , gypsum or portland cement plaster 22 2 3/4 3/4 Reinforced ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles