Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 88
Page 45
... cent . ( b ) Areas of Buildings Over One Story . The total area of all floors of multistory buildings shall not exceed 200 per cent of the area allowed for one - story buildings . No single floor area shall exceed that permitted for one ...
... cent . ( b ) Areas of Buildings Over One Story . The total area of all floors of multistory buildings shall not exceed 200 per cent of the area allowed for one - story buildings . No single floor area shall exceed that permitted for one ...
Page 124
... cent to 50 per cent until tested . Prisms shall be capped and tested in compression similar to tests for molded concrete cylinders as specified in U.B.C. Standard No. 26-10-64 . D. Sampling . Not less than five specimens shall be made ...
... cent to 50 per cent until tested . Prisms shall be capped and tested in compression similar to tests for molded concrete cylinders as specified in U.B.C. Standard No. 26-10-64 . D. Sampling . Not less than five specimens shall be made ...
Page 170
... cent and for compression perpendicular to grain shall be reduced one - third . The allowable unit stresses as set forth in Tables No. 25 - A , No. 25 - D , No. 25 - E and No. 25 - F and adjustments thereof , and stresses as set forth in ...
... cent and for compression perpendicular to grain shall be reduced one - third . The allowable unit stresses as set forth in Tables No. 25 - A , No. 25 - D , No. 25 - E and No. 25 - F and adjustments thereof , and stresses as set forth in ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles