Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 48
Page 43
... Fire - Resistive , " " Three- Hour Fire - Resistive , " " Two - Hour Fire - Resistive , " and " One- Hour Fire ... assembly having a three - hour fire - resistive rating . The total width of all openings in any three - hour fire ...
... Fire - Resistive , " " Three- Hour Fire - Resistive , " " Two - Hour Fire - Resistive , " and " One- Hour Fire ... assembly having a three - hour fire - resistive rating . The total width of all openings in any three - hour fire ...
Page 369
... fire protection . Structural 2. Reinforcing . Thickness of protection for concrete or Members masonry reinforcement ... ASSEMBLY . Fire assembly is the assembly of a fire door , fire window , or fire shutter , including of Openings all ...
... fire protection . Structural 2. Reinforcing . Thickness of protection for concrete or Members masonry reinforcement ... ASSEMBLY . Fire assembly is the assembly of a fire door , fire window , or fire shutter , including of Openings all ...
Page 384
... fire assembly required to have a three - hour or two - hour fire- resistive rating . Fire - Resistive Assemblies for Protection of Openings ( Continued ) Roof Coverings The area of glazed openings in fire assemblies required to have one ...
... fire assembly required to have a three - hour or two - hour fire- resistive rating . Fire - Resistive Assemblies for Protection of Openings ( Continued ) Roof Coverings The area of glazed openings in fire assemblies required to have one ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles