Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 47
Page 62
... doors or windows of the same building shall be protected by a fire assembly having a three - fourths - hour fire - resistive rating . Such fire assemblies shall be fixed , automatic , or self - closing . Every room containing a boiler ...
... doors or windows of the same building shall be protected by a fire assembly having a three - fourths - hour fire - resistive rating . Such fire assemblies shall be fixed , automatic , or self - closing . Every room containing a boiler ...
Page 384
... fire assembly required to have a three - hour or two - hour fire- resistive ... doors have observation panels the total area of the glazed openings shall ... fire - resistive assemblies are required to have a three - fourths- hour fire ...
... fire assembly required to have a three - hour or two - hour fire- resistive ... doors have observation panels the total area of the glazed openings shall ... fire - resistive assemblies are required to have a three - fourths- hour fire ...
Page 424
... Fire Clay Refractories . Standard Specifications C27 of 3701 the A.S.T.M. CHAPTER 38 38-1-64 3802 38-2-64 3802 ... Doors and Shutters . Standard Subject 10 ( A ) , Underwriters ' Laboratories , Inc. Protection of Openings in Walls and ...
... Fire Clay Refractories . Standard Specifications C27 of 3701 the A.S.T.M. CHAPTER 38 38-1-64 3802 38-2-64 3802 ... Doors and Shutters . Standard Subject 10 ( A ) , Underwriters ' Laboratories , Inc. Protection of Openings in Walls and ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles