Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 44
Page 127
... Gypsum rectly to the weather or where subject to frequent or con- Masonry tinuous wetting . ( b ) Materials . Gypsum masonry shall be gypsum block or tile laid up in gypsum mortar composed of one part gyp- sum and not more than three ...
... Gypsum rectly to the weather or where subject to frequent or con- Masonry tinuous wetting . ( b ) Materials . Gypsum masonry shall be gypsum block or tile laid up in gypsum mortar composed of one part gyp- sum and not more than three ...
Page 377
... Gypsum or Portland Cement Plaster Solid Gypsum Wallboard Partition Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster Studless partition , incombustible runners , % " or 1/2 " plain gypsum lath , gypsum ...
... Gypsum or Portland Cement Plaster Solid Gypsum Wallboard Partition Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster Studless partition , incombustible runners , % " or 1/2 " plain gypsum lath , gypsum ...
Page 407
... Gypsum Lath 13 ga . 1 % " long , " diamond - head approximately 5 " 64 on center Gypsum Lath and Plaster Diaphragms ( Continued ) THICKNESS AND KIND OF PLASTER SHEAR VALUE 1/2 " Gypsum - sand or Gypsum - perlite or Gypsum- Vermiculite ...
... Gypsum Lath 13 ga . 1 % " long , " diamond - head approximately 5 " 64 on center Gypsum Lath and Plaster Diaphragms ( Continued ) THICKNESS AND KIND OF PLASTER SHEAR VALUE 1/2 " Gypsum - sand or Gypsum - perlite or Gypsum- Vermiculite ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles