... minimum area of total reinforcement shall be not less than 0.002 times the gross cross - sectional area of the wall , not more than two - thirds of which may be used in either direction . Principal wall steel shall be limited to the ...
... minimum area of total reinforcement shall be not less than 0.002 times the gross cross - sectional area of the wall , not more than two - thirds of which may be used in either direction . Principal wall steel shall be limited to the ...
Page 350
... minimum dimension of six inches ( 6 " ) . ( e ) Grease Filters . Approved grease filters or grease baffles shall be installed at the inlet of the exhaust system . ( f ) Air Velocity . Exhaust duct systems shall be so designed as to ...
... minimum dimension of six inches ( 6 " ) . ( e ) Grease Filters . Approved grease filters or grease baffles shall be installed at the inlet of the exhaust system . ( f ) Air Velocity . Exhaust duct systems shall be so designed as to ...
Page 417
... MINIMUM GLAZING REQUIREMENTS FIXED WINDOWS AND OPENABLE WINDOWS OTHER THAN HORIZONTAL SLIDING Up to GLASS AREA 6 Sq . Ft . § 6 to 14 Sq . Ft . 14 to 32 Sq . Ft . 32 to 50 Sq . Ft . Over 50 Sq . Ft . Minimum Frame Lap 1/4 " 1/4 " 3/8 " 1 ...
... MINIMUM GLAZING REQUIREMENTS FIXED WINDOWS AND OPENABLE WINDOWS OTHER THAN HORIZONTAL SLIDING Up to GLASS AREA 6 Sq . Ft . § 6 to 14 Sq . Ft . 14 to 32 Sq . Ft . 32 to 50 Sq . Ft . Over 50 Sq . Ft . Minimum Frame Lap 1/4 " 1/4 " 3/8 " 1 ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles