Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 43
Page 344
... pipe vents shall not originate in any unoccupied attic or concealed space and shall not pass through any attic , inside wall , concealed space nor through any floor or ceiling . No such vent shall extend more than three feet ( 3 ...
... pipe vents shall not originate in any unoccupied attic or concealed space and shall not pass through any attic , inside wall , concealed space nor through any floor or ceiling . No such vent shall extend more than three feet ( 3 ...
Page 357
... pipe for such purposes shall be located at or Standpipes : above the center line of such tanks . Incombustible ... pipe inlets shall be installed in the Basement first floor of every store , warehouse , or factory where there Pipe are ...
... pipe for such purposes shall be located at or Standpipes : above the center line of such tanks . Incombustible ... pipe inlets shall be installed in the Basement first floor of every store , warehouse , or factory where there Pipe are ...
Page 432
... piping outlet with standard I.P.S. ( iron pipe size ) pipe , except as hereinafter provided . 2. Before any additional fuel connections may be made to existing fuel supply lines , pipe sizes shall be approved by the Building Official ...
... piping outlet with standard I.P.S. ( iron pipe size ) pipe , except as hereinafter provided . 2. Before any additional fuel connections may be made to existing fuel supply lines , pipe sizes shall be approved by the Building Official ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles