... side aisle of the row of seats at the rate of one pair of exit doors for each five rows of seats . Such exit doors ... Side Exits . Every auditorium and balcony of a Group A Occupancy shall be provided with exits on each side . The exits ...
... side aisle of the row of seats at the rate of one pair of exit doors for each five rows of seats . Such exit doors ... Side Exits . Every auditorium and balcony of a Group A Occupancy shall be provided with exits on each side . The exits ...
Page 375
... side construction . One cell in wall thickness . Plastered 31 Hollow Clay Tile , Wall End or side construction . Two cells in 8 " or less thickness . Unplastered 16 12 61 or 8 End or side construction . Two cells in 8 " or less ...
... side construction . One cell in wall thickness . Plastered 31 Hollow Clay Tile , Wall End or side construction . Two cells in 8 " or less thickness . Unplastered 16 12 61 or 8 End or side construction . Two cells in 8 " or less ...
Page 376
... side 134 " face Shells Unplastered 12 42 Plastered each side 9 24 " face Shells Unplastered 8 Solid Concrete Hollow Gypsum Blocks Unplastered Plastered each side Reinforcement not less than 0.2 % in each direction 5 4 21 61 51 41 31 51 ...
... side 134 " face Shells Unplastered 12 42 Plastered each side 9 24 " face Shells Unplastered 8 Solid Concrete Hollow Gypsum Blocks Unplastered Plastered each side Reinforcement not less than 0.2 % in each direction 5 4 21 61 51 41 31 51 ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles