Uniform Building Code, Volume 1International Conference of Building Officials, 1964 - Building laws |
From inside the book
Results 1-3 of 53
Page 332
... wire glass , except that skylights over vertical shafts extend- ing through two or more stories shall be glazed with plain glass as specified in this Section ; provided , that wire glass may be used if ventilation equal to not less than ...
... wire glass , except that skylights over vertical shafts extend- ing through two or more stories shall be glazed with plain glass as specified in this Section ; provided , that wire glass may be used if ventilation equal to not less than ...
Page 395
... Wire and Rigid Hangers MAXIMUM AREA SUPPORTED SIZE Single Hangers 8 sq . ft . 12 gauge wire Between Beams3 12 sq . ft . 10 gauge wire For Supporting Runners 16 sq . ft . 8 gauge wire Steel Wood 8 sq . ft . 16 gauge wire ( two loops ) ...
... Wire and Rigid Hangers MAXIMUM AREA SUPPORTED SIZE Single Hangers 8 sq . ft . 12 gauge wire Between Beams3 12 sq . ft . 10 gauge wire For Supporting Runners 16 sq . ft . 8 gauge wire Steel Wood 8 sq . ft . 16 gauge wire ( two loops ) ...
Page 403
... wire lath , or wire fabric lath on incombustible construction . 3Self - furring metal lath or self - furring wire fabric lath meets require- ments . In addition furring shall not be required on steel members having a flange width of one ...
... wire lath , or wire fabric lath on incombustible construction . 3Self - furring metal lath or self - furring wire fabric lath meets require- ments . In addition furring shall not be required on steel members having a flange width of one ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 34 |
Copyright | |
87 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit stresses appliances approved bars beam bending bolts Building Official building or structure ceiling cent chimney clearance Code column combustible compression compression members connectors Continued dead load designed diameter doors Douglas Fir dry standpipes ducts enclosures exceed exit exterior walls fiber fire assembly Fire Zone fire-resistive construction fire-resistive rating firestopped flange foot frame furnaces gauge girders grade Group grout gypsum height horizontal incombustible installed joints joists Laminations lath less live load located lumber masonry materials maximum metal minimum Modulus of Elasticity mortar nails occupant load one-hour fire-resistive openings partitions permitted plaster plate plywood portland cement pounds per square protected reinforced concrete resist roof shear sheathing slab space span specified in Section square feet square inch stairway standpipes steel studs surface Table thickness tion twelve inches 12 TYPES OF CONSTRUCTION U.B.C. Standard vent Ventilation vertical welds width wire wood Wood shingles