Pacific Coast Building Officials Conference. Creation of Department Powers and Duties of Building Official Unsafe Buildings CHAPTER 2 — ORGANIZATION AND ENFORCEMENT Sec . 201. There is hereby established in the city the " Build- ing ...
Pacific Coast Building Officials Conference. Creation of Department Powers and Duties of Building Official Unsafe Buildings CHAPTER 2 — ORGANIZATION AND ENFORCEMENT Sec . 201. There is hereby established in the city the " Build- ing ...
Page 23
Pacific Coast Building Officials Conference. tion thereof reported as dangerous or damaged and , if such Unsafe is found to be an unsafe building as defined in this Section , Buildings the Building Official shall give to the owner of such ...
Pacific Coast Building Officials Conference. tion thereof reported as dangerous or damaged and , if such Unsafe is found to be an unsafe building as defined in this Section , Buildings the Building Official shall give to the owner of such ...
Page 25
Pacific Coast Building Officials Conference. CHAPTER 3 - PERMITS AND INSPECTIONS Sec . 301. ( a ) Permits Required ... Official . ( b ) Application . To obtain a permit the applicant shall first file an application therefor in writing on ...
Pacific Coast Building Officials Conference. CHAPTER 3 - PERMITS AND INSPECTIONS Sec . 301. ( a ) Permits Required ... Official . ( b ) Application . To obtain a permit the applicant shall first file an application therefor in writing on ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
50 other sections not shown
Other editions - View all
Common terms and phrases
allowable angles applied approved bars beams bearing bending bolts bond building Building Official carried ceiling cement cent Class Code column compression concrete conform connections construction Cont'd covering designed determined diameter distance doors enclosures equal exceed exit extend face feet fire fire-resistive flange floor foot four framing girders grade grain Group gypsum height horizontal inches incombustible installed interior joints joists lath least length less load located masonry materials maximum metal nails occupancies one-half openings partitions permitted piles pipe placed plaster plate portion pounds per square protected reinforcement resistance rivets roof separated shear side slab solid space span specified specified in Section square feet square inch stairway steel story strength structural studs Subsection surface Table tests thickness Type U.B.C. Standard unit unit stress values vent vertical walls width wire wood