... furnaces shall be conducted into the blower housing from outside the furnace space by continuous air - tight ducts . Circulating air supply inlets for such furnaces shall not be located closer than ten feet ( 10 ′ ) from any appliance ...
... furnaces shall be conducted into the blower housing from outside the furnace space by continuous air - tight ducts . Circulating air supply inlets for such furnaces shall not be located closer than ten feet ( 10 ′ ) from any appliance ...
Page 267
... furnace shall be installed Floor in the floor of any aisle or passageway of any room used as Furnaces a place of public assembly or in any egress from such room . and No floor furnace shall be installed where it will extend Attic below ...
... furnace shall be installed Floor in the floor of any aisle or passageway of any room used as Furnaces a place of public assembly or in any egress from such room . and No floor furnace shall be installed where it will extend Attic below ...
Page 269
... furnace shall equal in square inches the cubic contents of all the rooms served by such warm air pipe divided by 40 ... Furnaces and Attic Furnaces Warm Air Ducts and Appurtenances Domestic Water Heaters.
... furnace shall equal in square inches the cubic contents of all the rooms served by such warm air pipe divided by 40 ... Furnaces and Attic Furnaces Warm Air Ducts and Appurtenances Domestic Water Heaters.
Contents
Part IAdministrative | 19 |
CHAPTER | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
42 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bolts Building Official building or structure ceiling cent Chimneys Code column combustible material compression compression members compressive strength conform connections Cont'd designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists lath and plaster least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plate portland cement pounds per square proscenium reinforced concrete resistance rivets shear side six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes structural steel studs Table tensile stress tests thickness twelve inches 12 twenty feet 20 Types of Construction U.B.C. Standard unit stress vent ventilation vertical openings width wood