... GRADE LUMBER Normal Loading - See also Section 2503 ( b ) , ( c ) ALLOWABLE UNIT STRESSES , POUNDS PER SQ . INCH Com- pression 1 Parallel to SPECIES AND COMMERCIAL GRADE Grain Com- pression ( Short Columns L / d = Perpen- dicular ...
... GRADE LUMBER Normal Loading - See also Section 2503 ( b ) , ( c ) ALLOWABLE UNIT STRESSES , POUNDS PER SQ . INCH Com- pression 1 Parallel to SPECIES AND COMMERCIAL GRADE Grain Com- pression ( Short Columns L / d = Perpen- dicular ...
Page 105
... Grade 1200 c Grade P. & T . 1,200 1075 c Grade P. & T . 1,075 Dense Structural S.E. & S . Dense No. 1 Structural No. 2 Dense J. & P . 1,025 Dense Select Structural 455 Dense Structural P. & T . Dense Structural S.E. & S . P. & T . Dense ...
... Grade 1200 c Grade P. & T . 1,200 1075 c Grade P. & T . 1,075 Dense Structural S.E. & S . Dense No. 1 Structural No. 2 Dense J. & P . 1,025 Dense Select Structural 455 Dense Structural P. & T . Dense Structural S.E. & S . P. & T . Dense ...
Page 229
... Grade A concrete 2 12 1 Grade B concrete 22 2 12 12 Grade C concrete 3 21/2 2 12 Brick of clay , shale , con- crete or sand - lime Clay tile , clay tile and concrete or concrete block ( see note 2 ) Solid gypsum blocks Hollow gypsum ...
... Grade A concrete 2 12 1 Grade B concrete 22 2 12 12 Grade C concrete 3 21/2 2 12 Brick of clay , shale , con- crete or sand - lime Clay tile , clay tile and concrete or concrete block ( see note 2 ) Solid gypsum blocks Hollow gypsum ...
Contents
Part IAdministrative | 19 |
CHAPTER | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
42 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bolts Building Official building or structure ceiling cent Chimneys Code column combustible material compression compression members compressive strength conform connections Cont'd designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists lath and plaster least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plate portland cement pounds per square proscenium reinforced concrete resistance rivets shear side six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes structural steel studs Table tensile stress tests thickness twelve inches 12 twenty feet 20 Types of Construction U.B.C. Standard unit stress vent ventilation vertical openings width wood