Uniform Building CodePacific Coast Building Officials Conference, 1949 - Building laws |
From inside the book
Results 1-3 of 29
Page 100
... Gypsum MIXTURE COMPRESSIVE STRENGTH ( Pounds per Sq . In . ) CLASS 1 Neat ( gypsum and wa- ter only ) 1800 2 Not more than 3 per cent by weight of wood chips , shavings or fiber 1000 3 Not more than 121⁄2 per cent by weight of wood ...
... Gypsum MIXTURE COMPRESSIVE STRENGTH ( Pounds per Sq . In . ) CLASS 1 Neat ( gypsum and wa- ter only ) 1800 2 Not more than 3 per cent by weight of wood chips , shavings or fiber 1000 3 Not more than 121⁄2 per cent by weight of wood ...
Page 229
... gypsum blocks Hollow gypsum blocks Poured gypsum 3 % 34 24 14 4 or 4 or 2 2 2 pl . 2 pl . 2 pl . 2 pl . 2 2 3 pl . 3 2 2 2 12 1 1 Metal lath and portland cement plaster 24 1 Metal lath and gypsum plaster 24 * Metal lath and gypsum ...
... gypsum blocks Hollow gypsum blocks Poured gypsum 3 % 34 24 14 4 or 4 or 2 2 2 pl . 2 pl . 2 pl . 2 pl . 2 2 3 pl . 3 2 2 2 12 1 1 Metal lath and portland cement plaster 24 1 Metal lath and gypsum plaster 24 * Metal lath and gypsum ...
Page 231
... gypsum lath , gypsum plastertt each side Incombustible studding with metal or wire lath . -in . plaster on each side Solid Concrete Hollow Gypsum Blocks Unplastered Plastered each side Hollow Wall of Reinforced Pneumatically Placed ...
... gypsum lath , gypsum plastertt each side Incombustible studding with metal or wire lath . -in . plaster on each side Solid Concrete Hollow Gypsum Blocks Unplastered Plastered each side Hollow Wall of Reinforced Pneumatically Placed ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
50 other sections not shown
Other editions - View all
Common terms and phrases
allowable angles applied approved bars beams bearing bending bolts bond building Building Official carried ceiling cement cent Class Code column compression concrete conform connections construction Cont'd covering designed determined diameter distance doors enclosures equal exceed exit extend face feet fire fire-resistive flange floor foot four framing girders grade grain Group gypsum height horizontal inches incombustible installed interior joints joists lath least length less load located masonry materials maximum metal nails occupancies one-half openings partitions permitted piles pipe placed plaster plate portion pounds per square protected reinforcement resistance rivets roof separated shear side slab solid space span specified specified in Section square feet square inch stairway steel story strength structural studs Subsection surface Table tests thickness Type U.B.C. Standard unit unit stress values vent vertical walls width wire wood