Page 79
... incombustible materials . Partitions , floors and roof construction shall be of incombustible ma- terials except as specified in this Chapter . Foundations shall be of masonry or concrete . Sec . 2102. Type IV buildings shall not exceed ...
... incombustible materials . Partitions , floors and roof construction shall be of incombustible ma- terials except as specified in this Chapter . Foundations shall be of masonry or concrete . Sec . 2102. Type IV buildings shall not exceed ...
Page 80
... incombustible material , provi : led , however , that a wood wearing surface or finish may be applied over such incombustible material . Sec . 2111. Roof construction may be of any type of con- struction permitted by this Code . Roof ...
... incombustible material , provi : led , however , that a wood wearing surface or finish may be applied over such incombustible material . Sec . 2111. Roof construction may be of any type of con- struction permitted by this Code . Roof ...
Page 231
... Incombustible studding with metal or wire lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster Reinforcement not less than 0.2 % in each direction 6 5 4 2 . 6 ° 5 ° 4 . 3 ° 5 * 4 ° 4 . 3 ° 2 . 2 . 2 ...
... Incombustible studding with metal or wire lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster Reinforcement not less than 0.2 % in each direction 6 5 4 2 . 6 ° 5 ° 4 . 3 ° 5 * 4 ° 4 . 3 ° 2 . 2 . 2 ...
Contents
Part IAdministrative | 19 |
CHAPTER | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
42 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bolts Building Official building or structure ceiling cent Chimneys Code column combustible material compression compression members compressive strength conform connections Cont'd designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists lath and plaster least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plate portland cement pounds per square proscenium reinforced concrete resistance rivets shear side six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes structural steel studs Table tensile stress tests thickness twelve inches 12 twenty feet 20 Types of Construction U.B.C. Standard unit stress vent ventilation vertical openings width wood