Page 218
... installed in the first floor of every store , warehouse or factory where there are cellars or basements under same , except where in such cellars or basements there is installed an automatic sprinkler system as specified by this Code ...
... installed in the first floor of every store , warehouse or factory where there are cellars or basements under same , except where in such cellars or basements there is installed an automatic sprinkler system as specified by this Code ...
Page 234
... installed when required in Sections 501 , 503 ( c ) and 3904 . Protection of Openings Class " B " fire doors shall be installed when required in Sections 503 ( c ) , 1807 , 3305 ( e ) , 3308 ( c ) , and 3309 ( d ) . Class " C " fire ...
... installed when required in Sections 501 , 503 ( c ) and 3904 . Protection of Openings Class " B " fire doors shall be installed when required in Sections 503 ( c ) , 1807 , 3305 ( e ) , 3308 ( c ) , and 3309 ( d ) . Class " C " fire ...
Page 267
... installed , unless conform- Equipment ing to Section 5105 , shall be constructed and installed as required for similar apparatus using solid fuel . Sec . 5109. ( a ) Location . No floor furnace shall be installed Floor in the floor of ...
... installed , unless conform- Equipment ing to Section 5105 , shall be constructed and installed as required for similar apparatus using solid fuel . Sec . 5109. ( a ) Location . No floor furnace shall be installed Floor in the floor of ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
50 other sections not shown
Other editions - View all
Common terms and phrases
allowable angles applied approved bars beams bearing bending bolts bond building Building Official carried ceiling cement cent Class Code column compression concrete conform connections construction Cont'd covering designed determined diameter distance doors enclosures equal exceed exit extend face feet fire fire-resistive flange floor foot four framing girders grade grain Group gypsum height horizontal inches incombustible installed interior joints joists lath least length less load located masonry materials maximum metal nails occupancies one-half openings partitions permitted piles pipe placed plaster plate portion pounds per square protected reinforcement resistance rivets roof separated shear side slab solid space span specified specified in Section square feet square inch stairway steel story strength structural studs Subsection surface Table tests thickness Type U.B.C. Standard unit unit stress values vent vertical walls width wire wood