Page 85
... LIVE AND DEAD LOADS Sec . 2301. Dead Load . The dead load of a building shall Definitions include the weight of the walls , permanent partitions , fram- ing , floors , roofs and all other permanent stationary con- struction entering ...
... LIVE AND DEAD LOADS Sec . 2301. Dead Load . The dead load of a building shall Definitions include the weight of the walls , permanent partitions , fram- ing , floors , roofs and all other permanent stationary con- struction entering ...
Page 86
... ( Load to be determined from pro- posed use or occupancy , but never less than ) 250 Stores - Retail ( Light Merchandise ) Wholesale ( Light Merchandise ) 75 ..100 ... LIVE LOADS 86 Sections 2304-2305 UNIFORM BUILDING CODE Unit Live Loads.
... ( Load to be determined from pro- posed use or occupancy , but never less than ) 250 Stores - Retail ( Light Merchandise ) Wholesale ( Light Merchandise ) 75 ..100 ... LIVE LOADS 86 Sections 2304-2305 UNIFORM BUILDING CODE Unit Live Loads.
Page 87
... live loads on one - half of the span if such loading results in reverse stresses , or stresses greater in any portion than the stresses produced by the required unit live load upon the entire span . For roofs whose structure is composed ...
... live loads on one - half of the span if such loading results in reverse stresses , or stresses greater in any portion than the stresses produced by the required unit live load upon the entire span . For roofs whose structure is composed ...
Contents
Part IAdministrative | 19 |
CHAPTER | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
42 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bolts Building Official building or structure ceiling cent Chimneys Code column combustible material compression compression members compressive strength conform connections Cont'd designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists lath and plaster least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plate portland cement pounds per square proscenium reinforced concrete resistance rivets shear side six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes structural steel studs Table tensile stress tests thickness twelve inches 12 twenty feet 20 Types of Construction U.B.C. Standard unit stress vent ventilation vertical openings width wood