Page 219
... proscenium opening . Sec . 3903. In buildings having a stage , the dressing room Rooms sections , workshops , and storerooms shall be located on the Accessory stage side of the proscenium wall and shall be separated from to Stage each ...
... proscenium opening . Sec . 3903. In buildings having a stage , the dressing room Rooms sections , workshops , and storerooms shall be located on the Accessory stage side of the proscenium wall and shall be separated from to Stage each ...
Page 220
... proscenium wall of a stage shall be pro- tected on each side by Class " A " fire doors . The proscenium opening , which shall be the main opening for viewing per- formances , shall be provided with a self - closing fire - resistive ...
... proscenium wall of a stage shall be pro- tected on each side by Class " A " fire doors . The proscenium opening , which shall be the main opening for viewing per- formances , shall be provided with a self - closing fire - resistive ...
Page 226
... proscenium curtain shall be supported on the proscenium wall by means of steel brackets of suitable size safely to carry the weight , or shall be mounted on structural steel beams . Blocks shall be installed so that the head - block is ...
... proscenium curtain shall be supported on the proscenium wall by means of steel brackets of suitable size safely to carry the weight , or shall be mounted on structural steel beams . Blocks shall be installed so that the head - block is ...
Contents
Part IAdministrative | 19 |
CHAPTER | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
42 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bolts Building Official building or structure ceiling cent Chimneys Code column combustible material compression compression members compressive strength conform connections Cont'd designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists lath and plaster least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plate portland cement pounds per square proscenium reinforced concrete resistance rivets shear side six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes structural steel studs Table tensile stress tests thickness twelve inches 12 twenty feet 20 Types of Construction U.B.C. Standard unit stress vent ventilation vertical openings width wood