Uniform Building CodePacific Coast Building Officials Conference, 1949 - Building laws |
From inside the book
Results 1-3 of 37
Page 181
... wire shall not be smaller than No. 4 gauge . For piles having a diameter twenty inches ( 20 " ) and larger , wire shall not be smaller than one - quarter inch ( 14 " ) round or No. 3 gauge . 4. Stresses . Pre - cast concrete piling ...
... wire shall not be smaller than No. 4 gauge . For piles having a diameter twenty inches ( 20 " ) and larger , wire shall not be smaller than one - quarter inch ( 14 " ) round or No. 3 gauge . 4. Stresses . Pre - cast concrete piling ...
Page 231
... wire lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster Reinforcement not less than 0.2 % in each direction 6 5 4 2 . 6 ° 5 ° 4 . 3 ° 5 * 4 ° 4 . 3 ° 2 . 2 . 2 . Hollow Stud Partition with Gypsum or ...
... wire lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster Reinforcement not less than 0.2 % in each direction 6 5 4 2 . 6 ° 5 ° 4 . 3 ° 5 * 4 ° 4 . 3 ° 2 . 2 . 2 . Hollow Stud Partition with Gypsum or ...
Page 244
... Wire lath Wire fabric 16 " 12 " 16 " 16 " Rod - stiffened or V - stiffened flat expanded metal lath of equal rigidity and weight is permissible on the same spacings as % -inch rib metal lath . ** Paper - backed wire fabric , No. 16 gauge ...
... Wire lath Wire fabric 16 " 12 " 16 " 16 " Rod - stiffened or V - stiffened flat expanded metal lath of equal rigidity and weight is permissible on the same spacings as % -inch rib metal lath . ** Paper - backed wire fabric , No. 16 gauge ...
Contents
Part IAdministrative | 19 |
CHAPTER | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
42 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bolts Building Official building or structure ceiling cent Chimneys Code column combustible material compression compression members compressive strength conform connections Cont'd designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists lath and plaster least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plate portland cement pounds per square proscenium reinforced concrete resistance rivets shear side six inches slab smoke pipe space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes structural steel studs Table tensile stress tests thickness twelve inches 12 twenty feet 20 Types of Construction U.B.C. Standard unit stress vent ventilation vertical openings width wood