... foundation , unless such footing or foundation is first properly underpinned or protected against settlement . Any person causing an excavation to be made on his own property , to a depth of twelve ( 12 ) feet , or less , below the ...
... foundation , unless such footing or foundation is first properly underpinned or protected against settlement . Any person causing an excavation to be made on his own property , to a depth of twelve ( 12 ) feet , or less , below the ...
Page 153
... foundation are not more than eight ( 8 ) inches in thickness . When built of concrete cast in place , foundation walls shall be at least as thick as the walls supported , but in no case less than eight ( 8 ) inches . When built of ...
... foundation are not more than eight ( 8 ) inches in thickness . When built of concrete cast in place , foundation walls shall be at least as thick as the walls supported , but in no case less than eight ( 8 ) inches . When built of ...
Page 217
... foundation below the woodwork of the build- ing on both the inside and outside surfaces . Such shield may be formed of a strip of non - corrodable metal firmly inserted in the surface of the masonry , or between the foundation and the ...
... foundation below the woodwork of the build- ing on both the inside and outside surfaces . Such shield may be formed of a strip of non - corrodable metal firmly inserted in the surface of the masonry , or between the foundation and the ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood