... Horizontal joints shall be lapped not less than two ( 2 ) inches and vertical joints not less than six ( 6 ) inches ... Horizontal and verti- cal joints of the metal reinforcing shall be lapped at least one full mesh . All horizontal ...
... Horizontal joints shall be lapped not less than two ( 2 ) inches and vertical joints not less than six ( 6 ) inches ... Horizontal and verti- cal joints of the metal reinforcing shall be lapped at least one full mesh . All horizontal ...
Page 163
... horizontal opening is provided , the allow- able areas tabulated may be increased fifteen ( 15 ) per cent and where more than one such exit is provided , such areas may be increased not to exceed twenty - five ( 25 ) per cent . Sec ...
... horizontal opening is provided , the allow- able areas tabulated may be increased fifteen ( 15 ) per cent and where more than one such exit is provided , such areas may be increased not to exceed twenty - five ( 25 ) per cent . Sec ...
Page 176
... horizontal , except where a booster fan is installed when such length shall not ex- ceed forty ( 40 ) feet . All such pipes under first floor joists shall have a uniform rise of at least one ( 1 ) inch per lineal foot of horizontal run ...
... horizontal , except where a booster fan is installed when such length shall not ex- ceed forty ( 40 ) feet . All such pipes under first floor joists shall have a uniform rise of at least one ( 1 ) inch per lineal foot of horizontal run ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood