Uniform Building Code, Volume 1930Pacific Coast Building Officials Conference, 1930 - Building laws |
From inside the book
Results 1-3 of 87
Page 74
... less in width than the wall framing supported thereon shall be placed under all walls or partitions that rest on ... less than five - eighths ( 5/8 ) of an inch thick , or ap- proved fiber - board not less than seven - sixteenths ( 7/16 ) ...
... less in width than the wall framing supported thereon shall be placed under all walls or partitions that rest on ... less than five - eighths ( 5/8 ) of an inch thick , or ap- proved fiber - board not less than seven - sixteenths ( 7/16 ) ...
Page 195
... less than two and two - tenths ( 2.2 ) sistive pounds per square yard and have not less than two and one- Floor half meshes per inch , or equivalent . Construc- Wood studs for bearing partitions or walls shall be not tion less than the ...
... less than two and two - tenths ( 2.2 ) sistive pounds per square yard and have not less than two and one- Floor half meshes per inch , or equivalent . Construc- Wood studs for bearing partitions or walls shall be not tion less than the ...
Page 200
... less than four layers of asphalt saturated rag felt , each layer weighing not less than fourteen ( 14 ) pounds to the one - hundred ( 100 ) square feet solidly mopped between with as- phalt so that in no place shall layer touch layer ...
... less than four layers of asphalt saturated rag felt , each layer weighing not less than fourteen ( 14 ) pounds to the one - hundred ( 100 ) square feet solidly mopped between with as- phalt so that in no place shall layer touch layer ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood