Uniform Building Code, Volume 1930Pacific Coast Building Officials Conference, 1930 - Building laws |
From inside the book
Results 1-3 of 44
Page 19
... located the main entrance and exit of such building . The main floor of every Group A occupancy shall be located at or near the ground floor level . All exterior walls or parts of walls , except on street fronts , of Group A buildings ...
... located the main entrance and exit of such building . The main floor of every Group A occupancy shall be located at or near the ground floor level . All exterior walls or parts of walls , except on street fronts , of Group A buildings ...
Page 26
... located at or near ground floor level , in which case all exits shall be at street level or shall meet street level ... located the main entrance and exit of such building , or such building may be connected to the street by an entrance ...
... located at or near ground floor level , in which case all exits shall be at street level or shall meet street level ... located the main entrance and exit of such building , or such building may be connected to the street by an entrance ...
Page 176
... located in or near the wall of the room nearest the furnace . No register shall be located in outside walls except in cases of absolute necessity . Where double registers are supplied by one leader pipe each register shall have a ca ...
... located in or near the wall of the room nearest the furnace . No register shall be located in outside walls except in cases of absolute necessity . Where double registers are supplied by one leader pipe each register shall have a ca ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood