Uniform Building Code, Volume 1930Pacific Coast Building Officials Conference, 1930 - Building laws |
From inside the book
Results 1-3 of 52
Page 1
... portion or portions of an existing building is changed and such portion or portions are segregated as specified in Section 503 of this Code then only such portion or portions of the build- ing need be made to comply with said ...
... portion or portions of an existing building is changed and such portion or portions are segregated as specified in Section 503 of this Code then only such portion or portions of the build- ing need be made to comply with said ...
Page 8
... portion thereof is being used or occupied contrary to the provisions of this Code the Building Inspector shall order such use or occupancy discontinued and the building or portion thereof vacated by notice served on any person using or ...
... portion thereof is being used or occupied contrary to the provisions of this Code the Building Inspector shall order such use or occupancy discontinued and the building or portion thereof vacated by notice served on any person using or ...
Page 12
... portion thereof , which is designed , built , rented , leased , let or hired out to be oc- cupied , or which is occupied as the home or residence of three or more families living independently of each other and doing their own cooking ...
... portion thereof , which is designed , built , rented , leased , let or hired out to be oc- cupied , or which is occupied as the home or residence of three or more families living independently of each other and doing their own cooking ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood