Uniform Building Code, Volume 1930Pacific Coast Building Officials Conference, 1930 - Building laws |
From inside the book
Results 1-3 of 49
Page 60
... similar projections shall be constructed of incombustible materials with walls , floors and roofs as specified in this Chapter and as specified in Chapter 35 . Porches and exterior balconies shall be constructed of in- combustible ...
... similar projections shall be constructed of incombustible materials with walls , floors and roofs as specified in this Chapter and as specified in Chapter 35 . Porches and exterior balconies shall be constructed of in- combustible ...
Page 69
... similar projections shall be con- Projections structed of incombustible materials with walls , floors and roof from the as specified in this Chapter and in Chapter 35 . Building Porches and exterior balconies shall be constructed of in ...
... similar projections shall be con- Projections structed of incombustible materials with walls , floors and roof from the as specified in this Chapter and in Chapter 35 . Building Porches and exterior balconies shall be constructed of in ...
Page 97
... similar grade of Class B lumber . ( e ) Supplementary provisions to above allowable unit working stresses are : Studding , posts and similar load - bearing members shall not be inferior in quality to No. 2 Common Dimension . For joists ...
... similar grade of Class B lumber . ( e ) Supplementary provisions to above allowable unit working stresses are : Studding , posts and similar load - bearing members shall not be inferior in quality to No. 2 Common Dimension . For joists ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood