Page 31
... stories 1 story 12,000 15,000 18,000 18,000 | 22,000 26,000 100 % Type IV 45 ft . 1 story 15,000 18,000 21,000 100 % Type V 100 % 35 ft . 2 stories 6,000 7,000 8,000 20 ft . 1 story 8,500 9,500 10,500 Note : - * Increase shall not be ...
... stories 1 story 12,000 15,000 18,000 18,000 | 22,000 26,000 100 % Type IV 45 ft . 1 story 15,000 18,000 21,000 100 % Type V 100 % 35 ft . 2 stories 6,000 7,000 8,000 20 ft . 1 story 8,500 9,500 10,500 Note : - * Increase shall not be ...
Page 41
... story 20,000 25,000 30,000 100 % Type III 55 ft . 20 ft . Type IV 45 ft . 5 stories 12,000 15,000 18,000 1 story 18,000 22,500 25,000 1 story 100 % 20,000 25,000 30,000 100 % Type V 35 ft . 20 ft . 3 stories 1 story 5,000 6,000 7,000 ...
... story 20,000 25,000 30,000 100 % Type III 55 ft . 20 ft . Type IV 45 ft . 5 stories 12,000 15,000 18,000 1 story 18,000 22,500 25,000 1 story 100 % 20,000 25,000 30,000 100 % Type V 35 ft . 20 ft . 3 stories 1 story 5,000 6,000 7,000 ...
Page 45
... story 20,000 25,000 30,000 Type III 55 ft . 20 ft . 5 stories 1 story 12,000 15,000 18,000 18,000 20,000 | 22,500 100 % Type IV 45 ft . 1 story 15,000 18,000 22,500 100 % Type V 35 ft . 20 ft . 3 stories 1 story 6,000 7,000 8,000 8,000 ...
... story 20,000 25,000 30,000 Type III 55 ft . 20 ft . 5 stories 1 story 12,000 15,000 18,000 18,000 20,000 | 22,500 100 % Type IV 45 ft . 1 story 15,000 18,000 22,500 100 % Type V 35 ft . 20 ft . 3 stories 1 story 6,000 7,000 8,000 8,000 ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood