Uniform Building Code, Volume 1930Pacific Coast Building Officials Conference, 1930 - Building laws |
From inside the book
Results 1-3 of 83
Page 63
... wood planking or of solid wood laminated construction not less than three and five - eighths ( 3 5/8 ) inches thick . Where wood partitions abutt or adjoin masonry walls they shall be tied as specified in Section 2507 . Temporary ...
... wood planking or of solid wood laminated construction not less than three and five - eighths ( 3 5/8 ) inches thick . Where wood partitions abutt or adjoin masonry walls they shall be tied as specified in Section 2507 . Temporary ...
Page 68
... wood and shall be designed and erected as specified in Chapter 26 for reinforced concrete , Chap- ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fireproofing of steel , iron or ...
... wood and shall be designed and erected as specified in Chapter 26 for reinforced concrete , Chap- ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fireproofing of steel , iron or ...
Page 175
... wood floor or other combustible material and where burners are Domestic not provided with a shield below , the wood or other combus- Water tible material shall be protected with a double metal shield Heaters and with a one ( 1 ) inch ...
... wood floor or other combustible material and where burners are Domestic not provided with a shield below , the wood or other combus- Water tible material shall be protected with a double metal shield Heaters and with a one ( 1 ) inch ...
Contents
PART IADMINISTRATIVE | 1 |
Enforcement | 8 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 16 |
Copyright | |
23 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation allowable asbestos balconies beams brick Building Inspector building or structure cent Chapter 43 chimneys coat Code columns combustible compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders grade Group A buildings Group H gypsum height horizontal inches inches in thickness inches thick incombustible materials joists less than four less than three live load lumber masonry or reinforced masonry walls maximum metal lath mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Portland cement pounds per square proscenium protected reinforced concrete seats slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet Stairs and Exits stairways stories street structural steel stucco studs thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood