Page XTC-27
... OSHPD ADOPTING AGENCY CA 1 2 DSA AC CA SFM DHS AGR BOC BSC SPCB DSA SS 1 2 3 4 DOSH * SL X Adopt entire California chapter * DOSH has not adopted the 1997 edition of the Uniform Building Code . The 1995 edition of the California ...
... OSHPD ADOPTING AGENCY CA 1 2 DSA AC CA SFM DHS AGR BOC BSC SPCB DSA SS 1 2 3 4 DOSH * SL X Adopt entire California chapter * DOSH has not adopted the 1997 edition of the Uniform Building Code . The 1995 edition of the California ...
Page 1-141
... OSHPD 1 ] 19B for concrete , Chapter 20A [ for OSHPD 1 ] 20B for light- weight metals , Chapter 21A [ for OSHPD 1 ] 21B for masonry , Chapter 22A [ for OSHPD 1 ] 22B for steel , Chapter 23A [ for OSHPD 1 ] 23B for wood , Chapter 25 for ...
... OSHPD 1 ] 19B for concrete , Chapter 20A [ for OSHPD 1 ] 20B for light- weight metals , Chapter 21A [ for OSHPD 1 ] 21B for masonry , Chapter 22A [ for OSHPD 1 ] 22B for steel , Chapter 23A [ for OSHPD 1 ] 23B for wood , Chapter 25 for ...
Page 1-142
... OSHPD 1 ] 21B . For precast concrete units , see Chapter 19A [ for OSHPD 1 ] 19B . For portland cement plaster , see Chapter 25A . Anchors , supports and ties shall be noncombustible and corro- sion resistant . When the terms ...
... OSHPD 1 ] 21B . For precast concrete units , see Chapter 19A [ for OSHPD 1 ] 19B . For portland cement plaster , see Chapter 25A . Anchors , supports and ties shall be noncombustible and corro- sion resistant . When the terms ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood