California Building Code, Volume 1International Conference of Building Officials, 1998 - Building laws |
From inside the book
Results 1-3 of 83
Page 1-15
... Type II - F.R . construction . Gymnasiums and similar occupancies may have floor surfaces constructed of wood or ... Type I , Type II - F.R . , Type II One - hour , Type III One - hour or Type IV construc- tion , except that the roof ...
... Type II - F.R . construction . Gymnasiums and similar occupancies may have floor surfaces constructed of wood or ... Type I , Type II - F.R . , Type II One - hour , Type III One - hour or Type IV construc- tion , except that the roof ...
Page 1-43
... Type I facilities and 70 square feet ( 6.5 m2 ) of floor area in Type II and Type III facilities ; 3. Have a minimum clear ceiling height of 8 feet ( 2438 mm ) and a minimum width of 6 feet ( 1829 mm ) ; 4. Contain a water closet , wash ...
... Type I facilities and 70 square feet ( 6.5 m2 ) of floor area in Type II and Type III facilities ; 3. Have a minimum clear ceiling height of 8 feet ( 2438 mm ) and a minimum width of 6 feet ( 1829 mm ) ; 4. Contain a water closet , wash ...
Page 1-61
... type that meets the minimum requirements based on occupancy even though cer- tain features of such building actually conform to a higher type of construction . When specific materials , types of construction or fire - resistive ...
... type that meets the minimum requirements based on occupancy even though cer- tain features of such building actually conform to a higher type of construction . When specific materials , types of construction or fire - resistive ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood