California Building Code, Volume 1International Conference of Building Officials, 1998 - Building laws |
From inside the book
Results 1-3 of 83
Page 1-4
... exceed 20 percent of the wall area facing the mall . 4. They shall not exceed a height of 36 inches ( 914 mm ) except that if the sign is vertical , then the height shall not exceed 96 inches ( 2438 mm ) and the width shall not exceed ...
... exceed 20 percent of the wall area facing the mall . 4. They shall not exceed a height of 36 inches ( 914 mm ) except that if the sign is vertical , then the height shall not exceed 96 inches ( 2438 mm ) and the width shall not exceed ...
Page 1-199
... exceed those set forth in Table 21 - N . 2109.5 Lateral Support . Masonry walls shall be laterally sup- ported in either the horizontal or vertical direction not exceeding the intervals set forth in Table 21 - O . Lateral support shall ...
... exceed those set forth in Table 21 - N . 2109.5 Lateral Support . Masonry walls shall be laterally sup- ported in either the horizontal or vertical direction not exceeding the intervals set forth in Table 21 - O . Lateral support shall ...
Page 1-276
... exceed 331/3 percent of the floor area of the room or space shel- tered by the roof when CC1 materials are used and ... exceed 30 square feet ( 2.8 m2 ) . 4. The area of approved plastic materials when used in required means of egress as ...
... exceed 331/3 percent of the floor area of the room or space shel- tered by the roof when CC1 materials are used and ... exceed 30 square feet ( 2.8 m2 ) . 4. The area of approved plastic materials when used in required means of egress as ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood