... exterior exit door that meets the requirements of Section 1003.3.1.3 . 1005.3.2.2 Detailed requirements . Exterior exit doors shall comply with the applicable requirements of Section 1003.3.1 . 1005.3.2.3 Arrangement . Exterior exit ...
... exterior exit door that meets the requirements of Section 1003.3.1.3 . 1005.3.2.2 Detailed requirements . Exterior exit doors shall comply with the applicable requirements of Section 1003.3.1 . 1005.3.2.3 Arrangement . Exterior exit ...
Page 1-118
... exit access serving as the refuge area shall comply with the requirements of Section 1004.2 based on the nor- mal ... exterior exit stairways , exterior exit ramps and exit courts , in addition to those common means of egress compo ...
... exit access serving as the refuge area shall comply with the requirements of Section 1004.2 based on the nor- mal ... exterior exit stairways , exterior exit ramps and exit courts , in addition to those common means of egress compo ...
Page 1-119
... exterior walls of the building . Any stairway not meeting the definition of an exterior stairway shall comply with the requirements for inte- rior stairways . 1006.3.3.2 ... exits and exit 1-119 1998 CALIFORNIA BUILDING CODE 1006.3.3.1.
... exterior walls of the building . Any stairway not meeting the definition of an exterior stairway shall comply with the requirements for inte- rior stairways . 1006.3.3.2 ... exits and exit 1-119 1998 CALIFORNIA BUILDING CODE 1006.3.3.1.
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood