California Building Code, Volume 1International Conference of Building Officials, 1998 - Building laws |
From inside the book
Results 1-3 of 4
Page 1-157
... factored load combinations do not exceed the factored ele- ment strength . The term " strength design " is used in the design of concrete and masonry structures . SECTION 1604 — STANDARDS - The standards listed below are recognized ...
... factored load combinations do not exceed the factored ele- ment strength . The term " strength design " is used in the design of concrete and masonry structures . SECTION 1604 — STANDARDS - The standards listed below are recognized ...
Page 1-178
... prestressed concrete . LOAD , DEAD , is the dead weight supported by a member , as defined by Section 1602 ( without load factors ) . LOAD , FACTORED , is the load , multiplied by 1-178 EXCERPTS FROM CHAPTER 19 1998 CALIFORNIA BUILDING ...
... prestressed concrete . LOAD , DEAD , is the dead weight supported by a member , as defined by Section 1602 ( without load factors ) . LOAD , FACTORED , is the load , multiplied by 1-178 EXCERPTS FROM CHAPTER 19 1998 CALIFORNIA BUILDING ...
Page 1-179
... factored loads or related internal moments and forces in such combinations as are stipulated in this code . See Section 1909.1.1 . STRESS is the intensity of force per unit area . STRUCTURAL CONCRETE is all concrete used for struc ...
... factored loads or related internal moments and forces in such combinations as are stipulated in this code . See Section 1909.1.1 . STRESS is the intensity of force per unit area . STRUCTURAL CONCRETE is all concrete used for struc ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood