... GROUT 2103.1 General . Mortar and grout shall comply with the provi- sions of this section . Special mortars , grouts or bonding systems may be used , subject to satisfactory evidence of their capabilities . when approved by the ...
... GROUT 2103.1 General . Mortar and grout shall comply with the provi- sions of this section . Special mortars , grouts or bonding systems may be used , subject to satisfactory evidence of their capabilities . when approved by the ...
Page 1-196
... grout mixing water and aggregate shall be heated to produce grout temperatures between 40 ° F and 120 ° F ( 4.5 ° C and 49 ° C ) . Masonry to be grouted shall be maintained above freezing dur- ing grout placement and for at least 24 ...
... grout mixing water and aggregate shall be heated to produce grout temperatures between 40 ° F and 120 ° F ( 4.5 ° C and 49 ° C ) . Masonry to be grouted shall be maintained above freezing dur- ing grout placement and for at least 24 ...
Page 1-201
... GROUT PROPORTIONS BY VOLUME1 AGGREGATE MEASURED IN A DAMP , LOOSE CONDITION Not less than 214 and not more than 3 ... grout 1 0 to 1/10 21/4 to 3 times the sum of the volumes of the cementitious materials Coarse 0 to 1/10 grout 1 to 2 ...
... GROUT PROPORTIONS BY VOLUME1 AGGREGATE MEASURED IN A DAMP , LOOSE CONDITION Not less than 214 and not more than 3 ... grout 1 0 to 1/10 21/4 to 3 times the sum of the volumes of the cementitious materials Coarse 0 to 1/10 grout 1 to 2 ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood