California Building Code, Volume 1International Conference of Building Officials, 1998 - Building laws |
From inside the book
Results 1-3 of 10
Page 1-157
... LOAD is the product of a load specified in Sec- tions 1606 through 1611 and a load factor . See Section 1612.2 for combinations of factored loads . LIMIT STATE is a condition in which a structure or compo- nent is judged either to be no ...
... LOAD is the product of a load specified in Sec- tions 1606 through 1611 and a load factor . See Section 1612.2 for combinations of factored loads . LIMIT STATE is a condition in which a structure or compo- nent is judged either to be no ...
Page 1-158
... load equal to 20 pounds per square foot ( psf ) ( 0.96 kN / m2 ) of floor area . EXCEPTION : Access floor systems ... combinations , including snow load , result in larger mem- bers or connections . For those conditions where light ...
... load equal to 20 pounds per square foot ( psf ) ( 0.96 kN / m2 ) of floor area . EXCEPTION : Access floor systems ... combinations , including snow load , result in larger mem- bers or connections . For those conditions where light ...
Page 1-175
... load combinations , including wind or earthquake loads , as permitted by Section 1612.3.2 . 3 May be increased the amount of the designated value for each additional foot ( 305 mm ) of depth to a maximum of 15 times the designated value ...
... load combinations , including wind or earthquake loads , as permitted by Section 1612.3.2 . 3 May be increased the amount of the designated value for each additional foot ( 305 mm ) of depth to a maximum of 15 times the designated value ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood