... openings . 311.9.3 Construction . Construction shall be of noncombus- tible materials . Open parking garages shall ... openings along the side shall not be less than 50 percent of the interior area of the side at each tier , and such ...
... openings . 311.9.3 Construction . Construction shall be of noncombus- tible materials . Open parking garages shall ... openings along the side shall not be less than 50 percent of the interior area of the side at each tier , and such ...
Page 1-49
... openings is first required due to location on property ; or 2. More than 12 inches ( 305 mm ) into areas where openings are prohibited . 503.2.2 Area of openings . When openings in exterior walls are required to be protected due to ...
... openings is first required due to location on property ; or 2. More than 12 inches ( 305 mm ) into areas where openings are prohibited . 503.2.2 Area of openings . When openings in exterior walls are required to be protected due to ...
Page 1-119
... openings . All openings in the exterior wall below and within 10 feet ( 3048 mm ) , measured horizontally , of an exterior exit stairway serving a building over two stories in height or a floor level having such openings in two or more ...
... openings . All openings in the exterior wall below and within 10 feet ( 3048 mm ) , measured horizontally , of an exterior exit stairway serving a building over two stories in height or a floor level having such openings in two or more ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood