Page XGC-2
... Shotcrete .. 2-170 Controlled Differential Movement of Section 1924 Shotcrete 2-170 Expansive Soils ) .... 2-60 Division V Section 1818 Appendix B ( Simplified Procedures for Design Standard for Reinforced Gypsum Concrete 2-171 Section ...
... Shotcrete .. 2-170 Controlled Differential Movement of Section 1924 Shotcrete 2-170 Expansive Soils ) .... 2-60 Division V Section 1818 Appendix B ( Simplified Procedures for Design Standard for Reinforced Gypsum Concrete 2-171 Section ...
Page 1-177
... Shotcrete . In addition to the requirements of Division II , design and construction of shotcrete structures shall meet the requirements of Division IV . 1900.4.3 Reinforced gypsum concrete . Reinforced gypsum concrete shall be in ...
... Shotcrete . In addition to the requirements of Division II , design and construction of shotcrete structures shall meet the requirements of Division IV . 1900.4.3 Reinforced gypsum concrete . Reinforced gypsum concrete shall be in ...
Page 1-433
... SHOTCRETE and PNEUMATICALLY PLACED PLASTER ) GUTTERS For roof drainage Should be kept free of obstructions GYMNASIUMS General Live loads ( for general floor design ) Special construction GYPSUM 208 Table 16 - B 1008.5.7 1008.5.7 3303.7 ...
... SHOTCRETE and PNEUMATICALLY PLACED PLASTER ) GUTTERS For roof drainage Should be kept free of obstructions GYMNASIUMS General Live loads ( for general floor design ) Special construction GYPSUM 208 Table 16 - B 1008.5.7 1008.5.7 3303.7 ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood