California Building Code, Volume 1International Conference of Building Officials, 1998 - Building laws |
From inside the book
Results 1-3 of 88
Page 1-74
... Smoke Dampers . Not less than Class II , 250 ° F ( 121 ° C ) smoke dampers complying with approved recognized standards ( see Chapter 35 , Part IV ) shall be installed and be accessible for inspection and servicing in the following ...
... Smoke Dampers . Not less than Class II , 250 ° F ( 121 ° C ) smoke dampers complying with approved recognized standards ( see Chapter 35 , Part IV ) shall be installed and be accessible for inspection and servicing in the following ...
Page 1-93
... smoke - control systems and smoke and heat venting systems . For requirements on fire alarm systems , see the following : SECTION 303.9 SUBJECT Group A , Divisions 1 and 2 Occupancies 305.2.3 , 305.9 Group E Occupancies 307.9 Group H ...
... smoke - control systems and smoke and heat venting systems . For requirements on fire alarm systems , see the following : SECTION 303.9 SUBJECT Group A , Divisions 1 and 2 Occupancies 305.2.3 , 305.9 Group E Occupancies 307.9 Group H ...
Page 1-100
... Smoke - control systems shall be activated as follows : 1. Mechanical smoke - control systems , using the pressuriza- tion method , serving buildings having no occupied floor more than 300 feet ( 91 440 mm ) above or 75 feet ( 22 860 mm ) ...
... Smoke - control systems shall be activated as follows : 1. Mechanical smoke - control systems , using the pressuriza- tion method , serving buildings having no occupied floor more than 300 feet ( 91 440 mm ) above or 75 feet ( 22 860 mm ) ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood