California Building Code, Volume 1International Conference of Building Officials, 1998 - Building laws |
From inside the book
Results 1-3 of 93
Page 1-111
... width shall be provided with not less than one inter- mediate handrail for each 88 inches ( 2235 mm ) of required width . Intermediate handrails shall be spaced approximately equally across with the entire width of the stairway ...
... width shall be provided with not less than one inter- mediate handrail for each 88 inches ( 2235 mm ) of required width . Intermediate handrails shall be spaced approximately equally across with the entire width of the stairway ...
Page 1-114
... width , and side , range and end aisles no less than 36 inches ( 914 mm ) in width . The required width of aisles shall be unobstructed . EXCEPTION : Handrails and doors , when fully opened , shall not reduce the required width by more ...
... width , and side , range and end aisles no less than 36 inches ( 914 mm ) in width . The required width of aisles shall be unobstructed . EXCEPTION : Handrails and doors , when fully opened , shall not reduce the required width by more ...
Page 1-114
... width . Handrails may project into the required aisle width a distance of 3/2 inches ( 89 mm ) . EXCEPTIONS : 1. Handrails may be omitted on ramped aisles having a slope not steeper than 1 unit vertical in 8 units horizontal ( 12.5 ...
... width . Handrails may project into the required aisle width a distance of 3/2 inches ( 89 mm ) . EXCEPTIONS : 1. Handrails may be omitted on ramped aisles having a slope not steeper than 1 unit vertical in 8 units horizontal ( 12.5 ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood