Page 1-76
... wire ties [ 0.08 ′′ ( 2 mm ) diameter ] at each course of tile or 3/8 " ( 9.5 mm ) metal mesh [ 0.046 " ( 1.2 mm ) diameter wire ] in horizontal joints ; limestone or trap - rock concrete fill1 extending 1 " ( 25 mm ) outside column on ...
... wire ties [ 0.08 ′′ ( 2 mm ) diameter ] at each course of tile or 3/8 " ( 9.5 mm ) metal mesh [ 0.046 " ( 1.2 mm ) diameter wire ] in horizontal joints ; limestone or trap - rock concrete fill1 extending 1 " ( 25 mm ) outside column on ...
Page 1-261
... wire , or combination wire and steel angle types , galvanized or coated with rust - resistive material . STRIPPING is flat reinforcing units of expanded metal or wire fabric or other materials not less than 3 inches ( 76 mm ) wide to be ...
... wire , or combination wire and steel angle types , galvanized or coated with rust - resistive material . STRIPPING is flat reinforcing units of expanded metal or wire fabric or other materials not less than 3 inches ( 76 mm ) wide to be ...
Page 1-271
... wire 0.145 - inch ( 4.19 mm ) ( No. 8 B.W. gage ) wire 3/16 " diameter , mild steel rod2 Hangers for suspended ceilings 20 7/32 " diameter , mild steel rod2 22.5 22.0 Single hangers between beams + 12 16 826 For supporting runners ...
... wire 0.145 - inch ( 4.19 mm ) ( No. 8 B.W. gage ) wire 3/16 " diameter , mild steel rod2 Hangers for suspended ceilings 20 7/32 " diameter , mild steel rod2 22.5 22.0 Single hangers between beams + 12 16 826 For supporting runners ...
Contents
Matrix Adoption Tables | XTC-3 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
UBC Standard 102 Stairway Identification | 1-105 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
1998 CALIFORNIA BUILDING 30 inches accordance applied approved assembly ASTM B.W. gage braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter concrete conform corridor curb ramps devices Division 3 Occupancies doors DOSH DSA/AC dwelling units elevator enclosure enforcing agency equipment exceed EXCEPTION exit exterior walls facilities Fire Code fire-resistive rating fixture floor area Group H grout gypsum handrails hazard HCD 1/AC height inches 51 mm installed joists least less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster pool portland cement protected ramp regulations reinforcement requirements of Section roof rooms Select Structural sheathing side slope smoke smoke detector space specified in Section square feet stairways steel storage studs surface Table Test thickness tion toilet Type UBC Standard Uniform Building Code veneer ventilation wallboard water closet wheelchair width wire wood