Uniform Building Code, Volume 1935International Conference of Building Officials, 1935 - Building laws |
From inside the book
Results 1-3 of 47
Page 127
... Standard Specifications and Tests for High Early Strengths Portland Cement , ( A. S. T. M. Designation C - 74-30T ) of the American Society for Testing Materials . ( b ) Concrete aggregates shall consist of natural sands , gravels ...
... Standard Specifications and Tests for High Early Strengths Portland Cement , ( A. S. T. M. Designation C - 74-30T ) of the American Society for Testing Materials . ( b ) Concrete aggregates shall consist of natural sands , gravels ...
Page 262
... Standard Methods of Testing Brick , A. S. T. M. Designation C67-31 of the American Society for Testing Materials . ( S. D. page 129. ) 3. Standard Specifications for Building Brick , A. S. T. M. Designation C62-30 of the American ...
... Standard Methods of Testing Brick , A. S. T. M. Designation C67-31 of the American Society for Testing Materials . ( S. D. page 129. ) 3. Standard Specifications for Building Brick , A. S. T. M. Designation C62-30 of the American ...
Page 263
... Standard Method of Test for Organic Impurities in Sands for Concrete , A. S. T. M. Designation C40-33 of the American Society for Testing Materials . ( S. D. page 66. ) 16. American Lumber Standards as set forth in " Sim- plified ...
... Standard Method of Test for Organic Impurities in Sands for Concrete , A. S. T. M. Designation C40-33 of the American Society for Testing Materials . ( S. D. page 66. ) 16. American Lumber Standards as set forth in " Sim- plified ...
Contents
PART IADMINISTRATIVE | 21 |
Enforcement | 28 |
PART IIIREQUIREMENTS BASED ON OCCUPANCY | 37 |
2 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation beams brick Building Inspector building or structure buildings For Group ceiling cent chimneys coat Code column combustible material compression compression member construction as specified doors dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Grade Group A buildings Group H gypsum height horizontal inches thick incombustible joists less than four less than three live load masonry or reinforced maximum metal lath minimum mortar occupancy one-half one-hour fire-resistive construction partitions permitted plaster Portland cement pounds per square proscenium protected reinforced concrete roofing felt shear side slab smoke pipe Society for Testing solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street strength structural steel stucco studs tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood